Unit 7: Replacement Procedures
GL4xxe Series Service Manual
7-27
INTERNAL REWINDER RETRACTION BASE-PLATE REMOVAL
The ribbon-end sensor informs the operator when ribbon stock has been exhausted and reloading is required.
1. Remove the Internal Rewinder’s front cover if it is in place. See “INTERNAL REWINDER FRONT COVER
REMOVAL” on page 7-25
2. Remove four screws (1) as shown in Figure 7-22 to remove the retraction base plate (2).
Figure 7-22, Internal Rewinder Retraction Base Plate Removal
NOTE: Ensure all loose components are properly positioned before you tighten the
associated screws.