3. Calculate the starting point voltage using the formula.
4. Use the LINE key to step the counter to the desired setting.
The display will increment one step for each time the LINE
key is pressed. If the LINE key is held pressed for more
than two seconds, it will automatically
go into the fast scroll
mode. The reading will advance to a setting of 4.9 (the
maximum voltage) after which it will automatically wrap and
start at
“0.0”
again. If a value of
“0.0”
is set, the printer will
automatically set the level each time the printer is powered
on with labels loaded and the head is closed.
5. Once the setting iscorrect, pressing the FEED key will
accept the setting and advance the next display.
Pa
e 3-22 SATO
“Se”
Print En
ines
EYE [
.XXV]
INPUT
X.XV
EYE - When setting the
“eye”
threshold, the voltage must be
measured with nothing but the label under the sensor and
then again withthe printed
“eye”
mark under the sensor. The
formula for this is:
(High Voltage Level + Low Voltage Level) x 0.5 = Start Value
1. Insert a label into the sensor and close the Label
Hold-Down. Make sure the printed
“eye”
mark is not under
the sensor. Record the voltage shown on the top line of the
LCD panel. This line should have the message
“EYE”
on the
top line (DIP switch DSW2-2 = ON).
2. Now pull the label forward until the
“eye”
mark is positioned
under the sensor (the voltage reading should be at its
highest point). Record the voltage shown on the top line of
the LCD panel. The voltage ranges measured should be
within the following ranges:
Eye-Mark = 2.5V to 3.5V
Label Only = Less than 1.0V
If the measured
values are outside this range, you may
have trouble in finding a value that will work properly under
all conditions. If this is the case, a higher quality label may
be needed to get adequate performance.
3. Calculate the starting point voltage using the formula.
4. Use the LINE key to step the counter to the desired setting.
The display will increment one step for each time the LINE
key is pressed. If the LINE key is held pressed for more
than two seconds, it will automatically
go into the fast scroll
mode. The reading will advance to a setting of 4.9 (the
maximum voltage) after which it will automatically wrap and
start at
“0.0”
again. If a value of
“0.0”
is set, the printer will
automatically set the level each time the printer is powered
on with labels loaded or the head is closed.
5. Once the setting is correct, pressing the FEED key will
accept the setting and advance to the Online Feed display.